RadOMA CCD Array Spectroradiometers

As the inventors of the first high-performance, computer-controlled spectroradiometers for LED testing, Gamma Scientific has continued to set the standard in spectroradiometer accuracy and reliability. Gamma Scientific spectroradiometers are trusted by the world’s leading organizations to provide accurate measurements.

Gamma Scientific spectroradiometers feature a proprietary optical design and back thinned CCD technology that provides exceptional low-light measurements, superior blue light sensitivity and highly accurate measurements of wavelength, color and power.

Original system calibration is performed in Gamma Scientific’s accredited laboratory using NIST-traceable standards. Gamma Scientific spectroradiometers can be self-calibrated and do not have to be returned to the factory for calibration.

Request a Quote
GS-1290 Spectroradiometers

GS-1290 spectroradiometers provide high accuracy and near perfect repeatability. Multiple models cover UV, Visible and near-IR wavelengths for use in a wide range of testing applications. GS-1290 spectroradiometers are designed for laboratory use and quality control applications.

 

Visit Product Page
GS-1220 Spectroradiometers

RadOMA GS-1220 spectroradiometers are optimized for quality control and high speed LED testing applications, with up to 100 ms optical integration time. GS-1220 spectroradiometers are built for seamless integration with production lines and quality control testing applications to capture highly accurate measurements of wavelength, color and power.

 

Visit Product Page

Features

  • Multiple models covering UV, Visible and near-IR wavelength ranges
  • Large dynamic range and low stray light
  • Exceptional accuracy via high-resolution bandwidth coverage
  • Near real time (millisecond) measurement speed
  • High sensitivity and spectral resolution
  • High-quality TE cooled back-thinned CCD detector for high sensitivity and stability
  • Superior wavelength and color accuracy
  • Thermal and mechanical stability
  • NIST-traceable field-calibration
  • Self-calibration (system never has to be returned for calibration)

GS-1290 Spectroradiometer Models

Spectroradiometric measurement system (200-800 nm) with 2-meter UV fiber-optic probe, temperature stabilized, back illuminated CCD, shutter, 2.5 nm HPBW slit setting, USB interface and rack mountable case.

Spectroradiometric measurement system (360-1100 nm) with 2-meter fiber-optic probe, temperature stabilized, back illuminated CCD, shutter, 2.7 nm HPBW slit setting, USB interface and rack mountable case.

Spectroradiometric measurement system (200-1100 nm) with 2-meter UV fiber-optic probe, temperature stabilized, back illuminated CCD, shutter, 2.7 nm HPBW slit setting, USB interface and rack mountable case.

Spectroradiometric measurement system (360-950 nm) with 2-meter fiber-optic probe, temperature stabilized, back illuminated CCD, shutter, 2.5 nm HPBW slit setting, USB interface and rack mountable case.

GS-1220 Spectroradiometer Models

Spectroradiometric measurement system (250-900 nm) with 2-meter UV fiber-optic probe, temperature stabilized, back illuminated CCD, shutter, 2.5 nm HPBW slit setting and USB interface.

Spectroradiometric measurement system (360-900 nm) with 2-meter fiber-optic probe, temperature stabilized, back illuminated CCD, with shutter, 2.5 nm HPBW slit setting and USB interface.

Spectroradiometric measurement system (380-1100 nm) with 2-meter fiber-optic probe, temperature stabilized, back illuminated CCD, with shutter, 2.5 nm HPBW slit setting and USB interface.

Spectroradiometric measurement system (200-1100 nm) with 2-meter UV fiber-optic probe, temperature stabilized, back illuminated CCD, with shutter, 2.5 nm HPBW slit setting and USB interface.

Download Data Sheet (PDF)